How it works
Area needed = flow / velocity. With Q in l/min and v in m/s, the minimum inner diameter in mm is d = √(4 x Q / (60,000 x pi x v)) x 1000, which simplifies to d = 4.61 x √(Q / v).
Typical maximum velocities: 1.5 m/s for domestic water pipes, 0.5 to 1.0 m/s for heating pipes (quiet radiators), and up to 2 m/s for short connections. Higher velocity means more noise, pressure loss and wear.
Example: 20 l/min at 1.5 m/s needs at least 16.8 mm inside, so a 22 x 1 copper pipe (20 mm bore) is the suggestion. Long runs, many bends or low supply pressure may need one size bigger.
Results are estimates for planning. Check product data sheets, local building rules and an engineer's calculations where required.
Frequently asked questions
What pipe size for a house water supply?
A typical family home uses about 25 to 35 l/min at peak, which usually means a 28 mm copper or 32 mm PEX supply pipe to the house.
What velocity should water have in a pipe?
Keep domestic water at or below about 1.5 m/s and heating water at 0.5 to 1 m/s. Above 2 m/s you start to hear the water.
Why does inner diameter differ from the size name?
Copper and PEX are named by outer diameter and wall thickness, and steel by an old inch size. The bore is what carries the water, so the calculator uses it.