How it works
Ohm's law links voltage, current and resistance: U = I x R. Power is P = U x I. Combining the two gives P = I² x R and P = U² / R, so any two known values are enough to find the other two.
Example: a 2,300 W heater on 230 V draws I = P / U = 10 A, and its element has a resistance of R = U² / P = 23 Ω.
The formulas assume a purely resistive load (heaters, kettles, incandescent bulbs). Motors and electronics have a power factor below 1, so use the power and current calculator for those.
Safety: measure and work on circuits only when they are switched off and checked dead. In Denmark, work on fixed installations must be done by an authorised electrician (autoriseret elinstallatør).
Results are estimates for planning. Check product data sheets, local building rules and an engineer's calculations where required.
Frequently asked questions
What is Ohm's law in simple terms?
The current through a conductor equals the voltage divided by the resistance (I = U / R). Double the voltage and the current doubles; double the resistance and the current halves.
How do I calculate watts from volts and amps?
Multiply them: P = U x I. A device drawing 5 A at 230 V uses about 1,150 W. For three-phase or motor loads you also need the power factor.
Why does a cold light bulb show a lower resistance?
Metal resistance rises with temperature. A filament can have ten times higher resistance when hot, so Ohm's law with the cold value overestimates the running current.